HWH Hydraulic Leveling Systems
HWH Corporation manufactures the most widely used hydraulic leveling systems in Class A motorhomes, as well as systems for some Class B and fifth wheel applications. These systems use a centrally mounted hydraulic pump to pressurize fluid that is then directed to individual cylinders at each leveling jack position through solenoid-controlled valves.


The hydraulic approach provides substantially more lifting force than electric systems - a hydraulic leveling system can handle a very unlevel site and support a fully loaded Class A motorhome without the motor strain issues that affect electric systems on the same sites. However, hydraulic systems add complexity: the fluid system must be maintained at the correct level, the pump must be in working order, and all solenoid valves must function correctly to direct fluid to the right jacks.
In Winter Haven's year-round outdoor storage environment, HWH systems face the specific challenge of hydraulic fluid degradation. Hydraulic fluid absorbs moisture over time, which reduces its viscosity and lubricity.
Fluid that has degraded significantly produces faster pump wear and solenoid valve sticking. Annual fluid check and biennial full fluid replacement is our recommendation for Polk County-stored motorhomes.
Diagnosing HWH Hydraulic Failures
HWH systems fail in identifiable patterns that guide our diagnosis. A system where all jacks fail to respond despite the pump running points to low fluid level, a failed pressure relief valve, or a blockage at the distribution manifold. We check fluid level first - a surprisingly common oversight.
A system where specific jacks won't respond while others work correctly points to a failed solenoid valve for the non-responding jack(s). Each jack has its own directional solenoid valve that opens to direct fluid to that cylinder. A sticking or failed solenoid valve can be tested with a 12V power probe to determine if the valve activates when direct power is applied - if it does, the problem is in the control circuit rather than the valve itself.
A pump that runs but produces no system pressure indicates either a failed pump (internal wear reducing output pressure) or a stuck-open pressure relief valve bypassing all pump output back to the reservoir. We test system pressure with a hydraulic gauge to distinguish between these faults.
Hydraulic cylinder failures produce jacks that extend or retract inconsistently, or that drift down under load despite being extended. Cylinder seals that have failed allow fluid to bypass the piston, reducing holding force. Cylinder replacement is a more involved repair but is performed on-site for accessible cylinder locations.