What Is It?
The Camco 40043 is a preset regulator that threads onto the campground pedestal's water outlet before your fresh water hose connects. It contains a spring-loaded diaphragm that limits outgoing pressure to approximately 45 to 65 PSI regardless of incoming line pressure. Available in both preset (fixed) and adjustable versions; the preset version is the most common and requires no tools or setup.
How We Use It as RV Technicians
Every plumbing repair call we make in Winter Haven starts with the question of what the pressure looks like at the source. We carry a pressure gauge and routinely test campground water pressure before connecting to customer rigs.
Municipal water supplies in Polk County's older distribution areas sometimes run 90 to 100 PSI. Some rural campgrounds with well-fed pressure tanks can spike to 120 PSI.
PEX tubing and fittings - the flexible plastic plumbing used in most RVs built after 2010 - are typically rated for 100 PSI but fail at joints and transition fittings long before that rating in real-world conditions involving temperature cycling and vibration. We have replaced PEX fittings under sinks, behind walls, and in the wheel well bay that failed from sustained high pressure in campgrounds across Winter Haven.
Why Every RV Owner in Winter Haven Should Have This
For $12, a water pressure regulator is the simplest insurance you can carry for your RV's plumbing system. Thread it on at every campground hookup and leave it in place. The one situation where this causes problems is at campgrounds with genuinely low pressure (below 30 PSI) where the regulator further reduces an already weak supply - but Winter Haven area campgrounds rarely have this issue.
We recommend the adjustable version to customers who camp at varied locations - it lets you increase pressure slightly if a campground has naturally low supply without removing the regulator entirely.
Real Job Story from Winter Haven
A travel trailer owner arrived at a lakeside campground in Auburndale for a two-week stay. On the third night, she woke to the sound of running water. A PEX fitting at the city water inlet coupling inside the compartment had separated, and unregulated 85 PSI city water had been running into her wheel well bay for approximately 20 minutes before she heard it.
We arrived the next morning. The fitting repair was straightforward - we cut back the PEX line, installed a new push-to-connect coupling, and pressure-tested the connection. But the water that had entered the wheel well bay had soaked into the plywood floor substrate in the storage bay above.
The fitting repair cost $95. Drying and treating the water-damaged floor substrate added another $180 in labor. Total: $275 for a situation that would not have occurred with a $12 pressure regulator in line.